1) Bohren CF, Huffman DR. Absorption and Scattering of light by smaall particle, New York:John Wiley & Sons 1987, p.7.
2) Iizuka K:The foundation of modern optical engineering, Tokyo:Ohmsha, Ltd;1980, p104-117
3) Nagai Y, Yamamoto S, Arai T, Sugisaki N, Ujiie M, Katagiri H, et al. Basic Studies of the Automated Blood Cell Analyzer Proto3 by Optical Fourier Transformation Technotogy (Part 1). J Jpn Society for Lab Hematology 2003;4:377-83.
4) Yoshizawa T:Apractical manual of optical measurement, Tokyo:Techno Consultants Inc. ;1985, p367-400
5) Takagi T. Development of a high-performance electrophretic light scattering apparatus for mobility determination of particles with their Stokes's of several nanometers. Applied and Throretical Electrophoresis 1990;1:273-8.
6) The Japan Society for Analytical Chemistry Ed. Electroanalytical technique;1987, p74-89, p101-105
7) Wallace H. Coulter. MEANS FOR COUNTING PARTICLES SUSPEND IN A FLUID. US PATENT 1953;2, 656, 508.
8) Wallace H. Coulter:High-speed automatic blood cell counter and cell size analyzer. Premliminary draft of a talk presented before the National Electronics Conference, Chicago, 1956
9) Bessman JD. Automated Blood Count and Differentials. Baltimore:The Johns Hopkins Univ. Pres;1984
10) Groner W, Simson E. Technology fundamentals. In:Groner W, Simson E, eds. Practical Guide to Modern Hematology Analyzers. New York, NY:Wiley & Sons;1995:21
11) Thom R. Method and results by improved electronic blood-cell sizing. Modern Concept in Hematology. Izak G, Lewis SM (Eds) , Academic Press, 191-199, 1972
13) Tatsumi N, Fukuda T, Kondo H. Standardization of clinical testing;Hematology. Japan Journal of Medical Technology 1991;40 (47) :91-96.
14) Mukai T, Mukai S. Reflection, Refraction, Diffraction and Scattering, Tokyo:Chijinshokan Co., Ltd. ;1984, p24-29, p84-85, p112-113, p121-123, p134-156
15) Tsuruta T:Multiple Scattering. Optics of wet sand and washed hair. Oplus E 1992;8:112-122
16) Takahashi, K. Fundamental aerosol engineering, Tokyo:Yokendo Co Ltd. ;1982, p145-166
17) Goodman JW. "Introduction to Fourie Optics", (McGrawhill, New York, 1968) p.63
18) Noguchi Y. New Bioseparation, Tokyo:CMC Publishing Co., Ltd. ;1988:p293-301
20) Nagai Y. The realization of white blood cell differential hematology analyzers by unstained method. Journal of Analytical Bio-Science 2003;26:303-10.
21) Edited by Yamamoto H, Sano K. The Manual of Medical Flow Cytometry 1st ed. 4-13, Kanehara Co. Ltd., Tokyo, Japan 1998
22) Salzman GC, Criwekk JM, Martin JC, Trujillo TT, Romero A, Mullaney PF, et al. Cell classification by laser light scattering:Identification and separation of unstained leukocytes. Acta Cytil 1975;19:374-7.
24) Nicola, N. A., Metcalf, D., von Melchner, H., Burgess,A. W. :Isolation of murine fetal hemopoietic progenitor cells and selective fractionation of various erythroid precursor, Blood, 58:376-386, 1981
26) Visser JWM, van den Engh GJ, van Bekkum DW. Light scattering properties of murine hematopoietic cells. Blood Cells 1908;6:391.
28) Sasaki T. Application of Cytometry. Fluorescent Dye. Tokyo:Igaku-Shoin Ltd. ;2000
29) Shapiro HM. Parameters and probe. Practical Flow Cytometry third edition. New York, John Wiley and Sons:1995. p229
31) Matsuzaki M, Ogawara M, Watanabe N. (Nakauchi H, eds). The Complete Control of Flow Cytometry, Tokyo:Shujunsha Co. Ltd. ;1999, p10-29
32) Caspersson T, Santesson L. Studies on protein metabolism in the cells of elialtumor. Acta Radiol 1942; (Suppl 46) :1.
35) Mitomo Y, Technique and Practice of Flow Cytometry, Tokyo:Kani-Shobo, 1984. p3.
37) Clinical and Laboratory Standards Institute;Reference Leukocyte Differential Count (Proportional) and Evaluation of Instrumental Methods;Approved Guideline, Wayne, PA:Clinical and Laboratory Standards Institute;1992. Document H20-A
39) Clinical and Laboratory Standards Institute;Evacuated tubes for blood specimen colledion;Approved Guideline, Wayne, PA:Clinical and Laboratory Standards lnstitute;2003. Document H1-A3
40) Clinical and Laboratory Standards Institute;Evaluation of Precision Performance of Quantitative Measurement Methods;Approved Guideline-Second Edition;Approved Guideline, Wayne, PA:Clinical and Laboratory Standards Institute;2004. Document EP5-A2
41) International Council for Standardization in Haematology Expert Panel on Cytometry. Guidelines for the evaluation of blood cell analyzers including those used for differential leukocyte and reticulocyte counting and cell marker applications, Clin Lab Haematol 1994:16:157-74.
42) Class II Special Controls Guidance Document:Premarket Notifications for Automated Differential Cell Counters for Immature or Abnormal Blood Cells;Final Guidance for Industry and FDA:Dec 4, 2001
43) Clinical and Laboratory Standards Institute;Evaluation of the Linearity of Quantitative Analytical Methods;Proposed Guideline;Approved Guideline, Approved Guideline, Wayne, PA:Clinical and Laboratory Standards Institute;2003, Document EP6-A
44) Clinical and Laboratory Standards Institute;Method Comparison and Bias Estimation Using Patient Samples;Approved Guideline-Second Edition;Approved Guideline, Wayne, PA:Clinical and Laboratory Standards Institute;2002, Document EP9-A2
45) Tatsumi N. The necessary of accreditation of medical laboratory. The Journal of the Japan Medical Association;134 (3). 2005. p.441-4.
46) Intrenational Council for Standarization in Haematology;Expert Panel on Haemoglobinometry:Recommenda-tions for reference method for haemoglobinometry in human blood. J Clin Pathol 1996;49:271-4.
47) Intrenational Committee for Standarization in Haematology;Expert Panei on Haemoglobinometry:Recommendations for reference method for haemoglobinometry in human blood and specification for international haemiglobincyanide reference preparation (3rd edition). Clin Lab Haematol 1987;9:73-9.
48) Clinical and Laboratory Standards Institute;Reference and Selected Procedures for the Quantitative Determination of Hemoglobin in Blood;Third Edition, Approved Guideline, Wayne, PA:Clinical and Laboratory Standards Institute;2000. Document H15-A3
49) International Committee for Standardization in Haematology;Recommendation for the reference method for the packed cell volume Lab. Hematol 2001;7:148-70.
50) International Committee for Standardization in Haematology;Recommendation for reference method for determination by centrifugation of packed cell volumeof blood. J Clin Pathol 1980;33:1-2.
51) International Committee for Standardization in Haematology;Recommended method for the determination of packed cell volume by centrifugation. WHO/LAB189. 1, 1989
52) Clinical and Laboratory Standards Institute;Procedure for Determining Packed Cell Volume by the Microhematocrit Method, Approved Guideline, Wayne, PA:Clinical and Laboratory Standards Institute;2000. Document H7-A3
53) Kazuo Niitani:Use of Indocyanine Green for the Determination of Trapped Plasma. Proceedings of the 5th ISQC-TOKYO, 1983. p.54-61.
55) WHO Calibration and control of basic blood cell counters. WHO/LAB/97. 2. 1-13.
56) Lewis SM. Control materials and calibrators. ln quality assurance in haematology. Eds. Lewis SM, Verwilghen RL Bailliere Tindall (London). 1988, p.110-17.
57) Clinical and Laboratory Standards Institute;Calibration and Quality Control Procedures of Automated Hematology Analyzers;Proposed Guideline, Wayne, PA:Clinical and Laboratory Standards Institute;1999. Document H38-P
60) International Committee for Standardization in Haematology;Recommended methods for the visual determination of white cell and platelet counts. WHO/LAB/88. 3, 1988
62) Clinical and Laboratory Standards Institute;Methods for Reticulocyte Counting (Automated Blood Cell Counters, Flow Cytometry, and Supravital Dyes) ;Approved Guideline-Second Edition, Wayne, PA:Clinical and Laboratory Standards Institute;2004. Document H44-A2
64) Clinical and Laboratory Standards Institute;Performance Goals for the Internal Quality Control of Multichannel Hematology Analyzers;Approved Guideline, Wayne, PA:Clinical and Laboratory Standards Institute;1996. Document H26-A
65) Watanabe K, Tatsumi N, Miwa S. JCCLS Proposal for Clinical Allowance on Values of Bloos Cell Count. The Japanese Journal of Clinical Pathology 1994;42:764-6.
66) Berend Houwen. The Differential Cell Count. Laboratory Hematology 2001;7:89-100.
67) Tokutake T, Baba H, Ishizaka A, Nozaki M, Kobayashi H, Ishida F:Platelet aggregation on peripheral blood spun smears may be useful for prediction of relapse in thrombotic thrombocytopenic purpura (TTP) :Journal of the Japanese Society for Lab Hematology;2004:183-191